Every system comes with an energy label and a set of initials, and almost nobody explains them. They are genuinely useful, they are the fairest comparison you have between two units, and they are also widely oversold. Here is what SEER and SCOP measure, how to read them without being misled, and the one important thing they cannot tell you.
In this guide
The two figures in one line each
SEER is the Seasonal Energy Efficiency Ratio. It describes how efficiently the system cools across a whole cooling season.
SCOP is the Seasonal Coefficient of Performance. It describes how efficiently the same system heats across a whole heating season.
Both are ratios of what you get out to what you put in, so in both cases a higher number is better. Both matter, because the systems we fit are reverse cycle and do both jobs. If you plan to use yours through the winter in a home office or a conservatory, the SCOP is arguably the more interesting of the two.
What a ratio of three actually means
This is the bit worth slowing down on, because it is where the numbers stop being abstract.
The figure tells you roughly how many units of heating or cooling you get for each unit of electricity you buy. So a system running at a ratio of about three is giving you around three units of useful heat for one unit of electricity. That is not a trick and it is not marketing. It happens because an air conditioner is a heat pump: it moves heat that already exists rather than creating any.
Compare that with a plug in fan heater. Every watt of electricity becomes a watt of heat, and it can never do better, because it is making the heat rather than fetching it. It is stuck at one for one. That is the whole reason air conditioning in heating mode beats an electric heater comfortably, and it is what these ratings are quietly measuring.
Why seasonal figures replaced the old ones
You will still see two older initials on some paperwork. EER and COP are the cooling and heating equivalents measured at a single set of test conditions, at one outdoor temperature, with the system at full output.
Seasonal ratings were introduced because that single snapshot was not describing how anything actually runs. SEER and SCOP are worked out across a range of outdoor temperatures and, crucially, across part load operation, weighted to represent a whole season rather than one moment.
That is a much better description of your life. Your system spends very little time at full output on the hottest possible day. It spends most of its time ticking over gently on an ordinary day.
The problem with a single measurement
The old figures had a specific blind spot. A single reading at full output flatters exactly the systems that are worst in real use, because full output is the one condition an old non-inverter system was built for.
A seasonal figure catches what happens the rest of the time: the throttling back, the holding steady, the gentle running that fills most of a season. That is where a modern inverter earns its keep, and it is why the gap between an inverter and a non-inverter looks modest on a single-point figure and considerable on a seasonal one. Our guide on inverter and non-inverter systems explains the mechanism behind that.
The energy label
The coloured arrows on the label are derived from these figures. The class is calculated from the seasonal rating, so it is a shorthand rather than separate information.
Two things are worth knowing. Cooling and heating are rated separately, so one system can carry different classes for each, and looking only at the one you assumed was important is an easy mistake. And the class boundaries are set in regulation, which means they get revised over time. A label is a snapshot of a scheme as it stood, not a permanent verdict, so we have deliberately not printed thresholds here that would be wrong within a couple of years.
What the ratings cannot tell you
Here is the honest part, and it is the reason we never sell on these numbers alone.
- They rate the box, not your installation. The figure comes from a laboratory testing the equipment. It knows nothing about your pipe runs, your siting, your commissioning or whether the charge is correct.
- They assume correct sizing. A high rated unit that is too small for the room runs flat out and never delivers what the label promised. Sizing beats specification.
- They are not a prediction of your bill. Your bill depends on your rooms, your habits, your set temperature, your insulation and your unit rate.
- They assume a maintained system. Nothing on the label survives filters that have not been cleaned in three years.
- They cannot compare a system with a heat pump or a boiler. Different jobs, different scopes.
So the fair way to use them is as a comparison between two units being considered for the same room, by the same installer, sized the same way. That is a genuinely useful comparison. What they are not is a league table you can shop from.
The climate assumption
One more thing worth knowing, because it explains why a headline figure can look optimistic. Seasonal heating figures are calculated against a defined reference climate rather than against your actual weather, and the headline number on a label refers to the standard reference zone.
Teesside is not that reference. Our winters are their own thing, and a coastal winter in Redcar or Saltburn is not a winter in Guisborough. The figure is still a fair basis for comparing two units, because both are measured the same way. It is just not a promise about a January in Middlesbrough, and anyone quoting it as one is overreaching.
How much should this decide your choice?
Less than the brochures suggest, and more than nothing.
It is worth caring about if the system will run a lot: a room you use daily, a conservatory, a home office you heat all winter. Over years of heavy use, the gap between a mid range and a high rated unit adds up, and that is a real argument for spending more.
It is worth caring about less if the system is for a bedroom used on a handful of hot nights. A premium rating on a unit that runs three weeks a year takes a very long time to pay you back, and that money is usually better spent on getting the sizing and the installation right. Our guide on what air conditioning costs to run goes through where the money actually goes.
Reading a quote across Teesside
When we quote, we tell you the seasonal figures for what we are proposing and why we chose that model for your room rather than a cheaper or dearer one. If a quote you have been given does not mention them, ask. If the answer is vague, that tells you something.
We are a family run business on North Ormsby Road in Middlesbrough covering roughly twenty miles of Teesside, including Stockton on Tees, Thornaby, Billingham, Norton, Yarm, Eaglescliffe, Ingleby Barwick, Redcar, Marske, Saltburn, Guisborough, Marton, Hartlepool, Peterlee and Darlington. The survey is free, and we will happily explain the label rather than wave it at you. Ring us on 01642 680 873.